The Steris 4085 Service Manual provides essential guidelines for maintaining and repairing the Steris 4085 General Surgical Table, ensuring optimal performance and patient safety in surgical settings.
1.1 Overview of the Steris 4085 General Surgical Table
The Steris 4085 General Surgical Table is a mobile, electrohydraulically operated table designed for versatility in surgical procedures. It supports cardiac, vascular, endoscopic, and orthopedic surgeries with adjustable positioning features.
Key features include lateral tilt, Trendelenburg/Reverse Trendelenburg, and a sliding tabletop for radiological access. Constructed from durable materials, it offers a load capacity of up to 1100 lbs. Controlled via hand, foot, or backup systems, it ensures precise patient positioning, making it a reliable choice for modern healthcare facilities.
1.2 Importance of the Service Manual for Maintenance and Repair
The Steris 4085 Service Manual is crucial for maintaining and repairing the surgical table, ensuring compliance with safety standards and optimal functionality. It provides detailed procedures for preventive maintenance, troubleshooting, and repair, helping technicians address issues like power malfunctions and mechanical failures. Adhering to the manual’s guidelines ensures patient safety, extends equipment lifespan, and minimizes downtime, making it an indispensable resource for healthcare facilities relying on the Steris 4085.
Key Features and Benefits of the Steris 4085
The Steris 4085 features a robust design with aluminum alloy and stainless steel construction, offering a sliding tabletop for radiological access and a high load capacity of 1100 lbs.
2.1 Design and Construction of the Surgical Table
The Steris 4085 is constructed with high-quality materials, including aluminum alloy and stainless steel, ensuring durability and longevity. Its large sliding tabletop provides unrestricted radiological access, while the electrohydraulic system offers smooth and precise patient positioning. The table is designed for mobility, with a self-leveling base, and features a load capacity of up to 1100 lbs, making it suitable for a wide range of surgical procedures. The design emphasizes patient safety, with features like Trendelenburg and lateral tilt functions, and is built to meet international safety standards, including UL and CSA certifications.
2.2 Patient Positioning Flexibility and Load Capacity
The Steris 4085 offers exceptional patient positioning flexibility, with powered functions like Trendelenburg, reverse Trendelenburg, lateral tilt, and height adjustments. The tabletop features a sliding mechanism for easy patient access and radiological procedures. Designed to accommodate various surgical needs, the table supports a maximum load capacity of 1100 lbs (499 kg) without positioning and 600 lbs (272 kg) with full patient positioning. This ensures stability and safety during complex procedures, making it versatile for cardiac, vascular, and orthopedic surgeries, among others.
2.3 Power Supply and Control Systems
The Steris 4085 operates using a dual power supply system, which includes an internal battery and facility electric power. This ensures uninterrupted functionality during procedures. The table can be controlled via a primary hand control, foot control, or backup hand control, providing ergonomic and convenient operation. The system includes features like ALS notification, maintenance alerts, and a locking mechanism to prevent unintended movements. These advanced controls enhance precision and ease of use, ensuring seamless patient positioning and operational efficiency in surgical environments.
Preventive Maintenance Schedule
Regular maintenance ensures the Steris 4085 operates safely and efficiently. Schedule inspections every 1,000 procedures, including lubrication of moving parts and battery checks to prevent downtime.
3.1 Recommended Maintenance Frequency
The Steris 4085 requires routine maintenance to ensure reliability and safety. It is recommended to perform preventive maintenance every 1,000 procedures or every three months, whichever comes first. Key tasks include lubricating moving parts, inspecting the battery and electrical systems, and checking for wear on components like the kidney elevator mechanism. Additionally, the manual advises verifying the proper function of the power supply and control systems. Regular maintenance helps prevent unexpected downtime and ensures the table operates within its design specifications for patient safety and optimal performance.
3.2 Preparatory Steps for Preventive Maintenance
Before performing preventive maintenance on the Steris 4085, ensure the table is powered off and the main power switch is in the “OFF” position. Remove the battery fuse to prevent accidental start-up. Consult the operator manual to locate components like the kidney elevator mechanism and primary fuses. Gather necessary tools and replacement parts, such as fuses and lubricants. Clear the area around the table to ensure safe access. Finally, review the maintenance schedule and procedures to prioritize tasks efficiently, ensuring compliance with safety guidelines and manufacturer recommendations.
Safety Guidelines and Precautions
Adhere to electrical safety protocols, ensure proper handling of fuses and components, and follow manufacturer guidelines to prevent accidents during Steris 4085 maintenance and ensure safety.
4.1 Electrical Safety and Fuse Protection
Ensure electrical safety by disconnecting power before servicing. Check fuses regularly to prevent system failures. Never replace fuses with incorrect ratings. Always refer to the manual for proper electrical procedures to avoid hazards and maintain compliance with safety standards.
4.2 Proper Handling of Surgical Table Components
Handle components with care to prevent damage. Use approved tools and avoid harsh chemicals. Follow torque specifications for bolts and screws. Store parts in a clean, dry environment. Transport components securely to prevent misalignment or breakage. Always refer to the manual for specific instructions on handling sensitive parts like the kidney elevator or tabletop. Proper handling ensures longevity and reliability of the surgical table, maintaining patient safety and operational efficiency.
Troubleshooting Common Issues
This section provides solutions for identifying and resolving common problems, such as power failures or mechanical malfunctions, ensuring the table operates smoothly during surgical procedures.
5.1 Identifying and Resolving Power-Related Problems
Power-related issues with the Steris 4085 often involve battery failure or electrical supply problems. Check the internal battery and facility power connections. Ensure fuses are intact and functioning. If using battery power, verify charge levels and recharge if necessary. For electrical issues, inspect the power cord and receptacle for damage. Refer to the manual for fuse replacement instructions. Always disconnect power before performing inspections or repairs to ensure safety. Consulting the service manual is crucial for resolving power-related malfunctions efficiently and safely.
5.2 Addressing Mechanical Malfunctions
Mechanical issues with the Steris 4085 may include faulty hydraulics or stuck tabletop mechanisms. Inspect the hydraulic lines for leaks or blockages. Lubricate moving parts if necessary. For tabletop malfunctions, ensure the Zip-Slide mechanism is clean and free of obstructions. Refer to the service manual for step-by-step troubleshooting. Always follow safety guidelines and use approved tools. If problems persist, contact certified STERIS technicians to prevent further damage and ensure reliable operation. Regular maintenance can help mitigate mechanical issues and extend the table’s lifespan.
Where to Find the Steris 4085 Service Manual
The Steris 4085 Service Manual can be downloaded from official STERIS websites, ManualsLib, or authorized medical equipment portals using part number P764333765 for quick access.
6.1 Official Sources for Downloading the Manual
The Steris 4085 Service Manual is available for download from the official STERIS website and authorized medical equipment portals like ManualsLib. Users can access the manual by visiting STERIS customer support pages or using part number P764333765 for direct download. Ensure to verify the source’s authenticity to avoid unauthorized versions. Official sources guarantee accurate and updated information, essential for proper maintenance and compliance with safety standards. Always prioritize downloading from trusted platforms to maintain equipment reliability and performance.
6.2 Additional Resources and Support
Beyond the manual, STERIS offers comprehensive support through their customer service hotline and online technical assistance. Users can access troubleshooting guides, maintenance schedules, and repair tips on the STERIS website. Additional resources include instructional videos and FAQs addressing common issues; For complex repairs, certified STERIS service technicians are available to ensure equipment longevity and safety. These resources complement the manual, providing a holistic approach to managing the Steris 4085 effectively. Utilize these support channels to maximize operational efficiency and minimize downtime.